Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
J. Health Biol. Sci. (Online) ; 7(2): 133-138, abr.-jun. 2019.
Article in English | LILACS | ID: biblio-1005701

ABSTRACT

Introduction: there are clinical situations in the management of cavities favorable to saliva contamination. Human saliva is a complex mixture of oral fluids and it has been showed that the protein content of the saliva is responsible for the decrease in adhesive bond strength when contamination has occurred. Objective: this study aimed to evaluate the effect of saliva contamination during different steps of application of adhesive system on bond strength of total etch two-step adhesive system. Methods: twenty-five extracted human molars were ground flat to expose occlusal dentin. The bonding system and composite resins were applied to the dentin after etching step under five conditions (n=5/group): G1: control group­no contamination; G2: etching/ contamination/dry/adhesive system application; G3: etching/contamination/wash/dry/adhesive system application; G4: etching/adhesive system application/contamination/wash/dry/adhesive system re-application; and G5: etching/adhesive system application/contamination/dry. Microtensile bond strength was tested after specimens were stored in distilled water at 37ºC for 24h. Data (mean values -µTBS) were analyzed by ANOVA one-way and Tukey tests (α=5%), respectively. Results: Groups G2, G3 and G4 revealed bond strength similar to the control (G1). Group G5 showed significantly lower bond strengths than other groups (p<0.001). Conclusion: the total etch two-step adhesive tolerated salivary contamination except when the contamination occurred after application of the bond and it was only removed with an air jet and adhesive system was not reapplied.


Introdução: a saliva humana é uma mistura complexa de fluidos orais e tem sido demonstrado que o conteúdo proteico da saliva é responsável pela diminuição da resistência adesiva quando ocorre contaminação. Objetivo: este estudo objetivou avaliar o efeito da contaminação salivar durante diferentes etapas de aplicação do sistema adesivo sobre a resistência de união. Métodos: vinte e cinco molares humanos extraídos foram cortados para exposição da dentina oclusal. O sistema adesivo convencional e as resinas compostas foram aplicados na dentina após a etapa de condicionamento sob cinco condições (n = 5 / grupo): G1: grupo controle - sem contaminação; G2: condicionamento ácido/contaminação/secagem/adesivo; G3: condicionamento ácido/contaminação/lavagem/secagem/adesivo; G4: condicionamento ácido/aplicação do sistema adesivo/contaminação/lavagem/secagem/reaplicação do sistema adesivo; e G5: condicionamento ácido/aplicação do sistema adesivo/contaminação/secagem. A resistência à microtração foi testada após o armazenamento das amostras em água destilada a 37ºC por 24 horas. Os dados (valores médios -µTBS) foram analisados por ANOVA unidirecional e testes de Tukey (α = 5%), respectivamente. Resultados: Os grupos G2, G3 e G4 revelaram resistência de união semelhante ao controle (G1). O grupo G5 apresentou resistência de união significativamente menor que os demais grupos (p <0,001). Conclusão: o adesivo convencional de dois passos não foi afetado pela contaminação salivar, exceto quando a contaminação ocorreu após a aplicação adesiva e foi removida apenas com jato de ar e o sistema adesivo não foi reaplicado.


Subject(s)
Dentin-Bonding Agents , Saliva , Dentin
2.
Odontol. clín.-cient ; 12(3): 227-230, Jul.-Set. 2013. tab
Article in Portuguese | LILACS | ID: lil-778254

ABSTRACT

O objetivo do presente estudo foi avaliar a resistência de união ao esmalte bovino de um sistema adesivo para compósitos à base de silorano, com e sem condicionamento prévio. Para isso, foram selecionados 12 incisivos bovinos com superfície de esmalte planificada e, então, divididos em dois grupos: Grupo 1 (P90) - realizado um platô em esmalte com o sistema restaurador P90; Grupo 2 (P90A) - realizado um platô com condicionamento ácido prévio à utilização do sistema adesivo, utilizando ácido fosfórico a 37% por 15s. Os espécimes (n=6) foram seccionados nos eixos "x" e "y" para obtenção de palitos para o teste de microtração com velocidade de 0,5mm/min. Os dados obtidos foram submetidos aos testes ANOVA One-way e Tukey. Os testes de microtração mostraram um aumento na resistência de união, quando utilizado o condicionamento ácido prévio ao sistema adesivo adotado no estudo (p<0,05). Concluiu-se que o condicionamento prévio com ácido fosfórico a 37% aumentou a resistência de união do sistema restaurador à base de silorano ao esmalte bovino.


The purpose of this study was to evaluate the bond strength produced by a Silorane-based restorative system to enamel with or without prior acid etching. Twelve bovine incisors were selected. Then, the enamel was planned. The teeth were divided into two groups: Group 1 - a plateau was built in the enamel planned with P90 system (P90); Group 2 - a plateau was built in the enamel with prior etching using 37% phosphoric acid for 15s (P90A). Specimens (n=6) were sectioned in enamel/composite sticks to microtensile testing. The cross-sectional area of the sticks was measured. Beams were pulled until failure and bond strength was calculated. Data were statistically analyzed using ANOVA One-way and Tukey (p=0,05). Microtensile bond strength showed higher values to group 2 (P90A), that used prior etching to the adhesive system tested in the study. In conclusion prior etching with phosphoric acid increased microtensile bond strength values of the Silorane-based composite on bovine enamel.

3.
RFO UPF ; 16(3)set.-dez. 2011.
Article in Portuguese | LILACS | ID: lil-621160

ABSTRACT

Objetivo: O objetivo deste estudo in vitro foi avaliar o nível de infiltração marginal em restaurações realizadas com sistemas restauradores à base de metacrilato e à base de silorano. Materiais e método: Cavidades classe V em forma de caixa (4 x 4 x 2mm) foram preparadas na junção cemento-esmalte nas faces vestibular, lingual, mesial e distal com margens em esmalte e dentina de vinte molares humanos hígidos. Os dentes foram divididos aleatoriamente em dois grupos e restaurados da seguinte forma: Grupo 1 (G1) - Clearfil SE, aplicado se-gundo as instruções do fabricante e restaurado com re-sina composta Filtek Z250, e Grupo 2 (G2) - P90 Bond, aplicado segundo as instruções do fabricante e restau-rado com resina composta Filtek P90. Resina composta foi aplicada em incremento único e fotopolimerizada por 40s. Os espécimes foram imersos em solução de azul de metileno a 2% por 4h e seccionados longitu-dinalmente no centro da restauração. A penetração de corante na interface adesiva foi avaliada usando-se lupa esterioscópica e escores de 0 a 3 foram atribuídos às margens de esmalte e dentina. A significância dos dados foi analisada utilizando-se os testes estatísticos Kruskall Wallis e Student-Newman-Keuls. Resultados: Não houve diferença estatística entre os dois sistemas restauradores testados tanto nas margens de dentina (P = 0,19) quanto nas margens de esmalte (P = 0,97). Conclusão: Não houve diferença na capacidade sela-dora dos materiais restauradores testados.

4.
RGO (Porto Alegre) ; 59(1): 51-58, jan.-mar. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-588578

ABSTRACT

OBJETIVO: Avaliar a resistência de união da interface adesiva de pinos de fibra de vidro (Reforpost nº 3 - Angelus) e dentina radicular. MÉTODOS: Vinte e quatro raízes de dentes humanos foram tratadas endodonticamente e desobstruídas até uma profundidade de 9mm e o pino cimentado com um dos três sistemas de fixação descritos a seguir (n = 8): Grupo 1 - sistema Single Bond 2 (3M ESPE, St. Paul, MN, EUA) / RelyX ARC (3M ESPE, St. Paul, MN, EUA); Grupo 2 - sistema ED Primer/Panavia 21 (Kuraray Medical Inc. Kurashiki, Japão); Grupo 3 - cimento RelyX Unicem (3M ESPE/AG. Seefeld, Alemanha). As raízes foram seccionadas em três porções correspondentes aos terços cervical, médio e apical. Os espécimes foram submetidos aos testes de push-out e os valores de resistência de união à análise de variância (ANOVA) e ao teste de Tukey (p< 0,05). RESULTADOS: Somente o Grupo 2 apresentou diferença estatística em relação aos terços, tendo o apical apresentado menor média. Para o terço cervical, o Grupo 3 apresentou maiores valores de resistência de união que o Grupo 2, tendo sido Grupo 1 estatisticamente semelhante aos outros dois materiais. Para os terços médio e apical, Grupo 2 apresentou resistência de união menor que Grupo 1 e Grupo 3, sendo estes estatisticamente iguais entre si. CONCLUSÃO: Os cimentos de presa dual (RelyX ARC, 3M ESPE, St. Paul, MN, EUA e RelyX Unicem, 3M ESPE, St. Paul, MN, EUA) promoveram maior resistência de união entre o pino endodôntico e as paredes do canal radicular do que o cimento quimicamente ativado (Panavia 21, Kuraray Medical Inc., Kurashiki, Japão).


OBJECTIVE: This study assessed the bond strength of the adhesive interface of fiber glass posts (Reforpost nº 3 - Angelus) to root dentin. METHODS: Twenty-four roots of human teeth were treated endodontically and drilled to a depth of 9mm. Posts were cemented using one of the following three systems (n = 8): group 1 (G1) - Single Bond 2 system (3M ESPE, St. Paul, MN, EUA) / RelyX ARC (3M ESPE, St. Paul, MN, EUA); group 2 (G2) ED Primer (Kuraray Medical Inc. Kurashiki, Japan) / Panavia 21 (Kuraray Medical Inc. Kurashiki, Japan) system; and group 3 (G3) RelyX Unicem (3M ESPE/AG. Seefeld, Germany) cement. The roots were sectioned into three parts corresponding to the coronal, middle and apical thirds. The specimens were submitted to the push-out test. Bond strength values were submitted to analysis of variance (ANOVA) and the Tukey's test (p< 0.05). RESULTS: Only G2 presented statistically significant differences among the three regions of the canal with the apical third presenting the lowest mean bond strength. In relation to the coronal third, G3 presented higher bond strengths than G2. G1 was statistically equal to the other two materials. Regarding the middle and apical thirds, the mean bond strength of G2 was significantly lower than those of G2 and G3, these two being statistically equal. CONCLUSION: The dual-cure cements (RelyX ARC, 3M ESPE, St. Paul, MN, EUA and RelyX Unicem, 3M ESPE, St. Paul, MN, EUA) promoted higher bond strengths between the endodontic post and root dentin than the self-cure cement (Panavia 21, Kuraray Medical Inc., Kurashiki, Japan).


Subject(s)
Humans , Post and Core Technique , Dentin-Bonding Agents , Resin Cements , Dentin , Shear Strength
SELECTION OF CITATIONS
SEARCH DETAIL